Product description
YCH305 self-cleaning COD sensor based on the principle of ultraviolet absorption method, by measuring the absorption degree of these organic compounds to 254nm wavelength ultraviolet light, can accurately measure the content of dissolved organic pollutants in water. One turbidity detection light source is integrated in the interior, and the turbidity interference of the measured water is automatically compensated. With automatic cleaning brush device, even long-term monitoring still has excellent stability.
Product Features:
Ø No reagents, no pollution, more economical and environmentally friendly.
Ø Automatically compensate for turbidity interference.
Ø With automatic cleaning brush to prevent biological attachment and longer maintenance cycle.
Ø Built-in calibration parameters for easy on-site use and secondary calibration.
Technical parameters:
Name | UV254 BOD Sensor(Low range) | UV254 BOD Sensor(High range) |
Model | YCH405-L | YCH405-H |
Principle | Ultraviolet absorption method | Ultraviolet absorption method |
Range | 0-300mg/L | 0-1500mg/L |
Accuracy | ±5%FS | ±5%FS |
Resolution | 0.01mg/L | 0.01mg/L |
Linearity | R2 > 0.99 | R2 > 0.99 |
Protection Level | IP68 | IP68 |
Output Signal | Support RS-485/Modbus protocol | Support RS-485/Modbus protocol |
Operating Temp. | 0-50℃ | 0-50℃ |
Assembly | Input Type | Input Type |
Power Supply | DC 9~12V, current < 50mA | DC 9~12V, current < 50mA |
Cable Length | 5 meters (default),Customizable | 5 meters (default),Customizable |
Housing Material | SS316/Titanium | SS316/Titanium |
Mounting Thread | G 3/4 | G 3/4 |
Shipping and returns
After payment, express products within 3 days, generally choose SF, if there is special logistics please inform in advance